SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Vascular and Endovascular Surgery
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Balink, H.
Right arrow Articles by Reijnen, M. M. P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Balink, H.
Right arrow Articles by Reijnen, M. M. P. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Diagnosis of Abdominal Aortic Prosthesis Infection With FDG-PET/CT

Hans Balink, MD

Department of Nuclear Medicine, Medical Centre Leeuwarden, Leeuwarden, hans.balink{at}znb.nl

Michel M. P. J. Reijnen, MD

Department of Surgery, Alysis Zorggroep, Locatie Rijnstate, Arnhem, The Netherlands

A 79-year-old man was referred with recurrent periods of fever and chills. Six years earlier an aortic bifurcation graft had been implanted. Blood examination showed elevated infection parameters. A regular computed tomographic (CT) scan in the previous hospital showed no signs of graft infection. When blood cultures revealed multiple enteric bacteria, a 2-deoxy-2-[F18]fluoro- d-glucose-positron emission tomographic/CT (FDG- PET/CT) scan was performed that demonstrated ring-shaped pathological uptake at the proximal anastomosis. The patient was operated on and an infected graft was found, with a 1-cm defect in the distal part of the duodenum. Bacterial cultures of the explanted graft were positive. The patient recovered well from surgery and is on a regimen of prolonged antibiotic and antimycotic treatment.

Key Words: aortic prosthesis • infection • FDG-PET/CT

Vascular and Endovascular Surgery, Vol. 41, No. 5, 428-432 (2007)
DOI: 10.1177/1538574407305094


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
JNMHome page
J. Wasselius, J. Malmstedt, B. Kalin, S. Larsson, A. Sundin, U. Hedin, and H. Jacobsson
High 18F-FDG Uptake in Synthetic Aortic Vascular Grafts on PET/CT in Symptomatic and Asymptomatic Patients
J. Nucl. Med., October 1, 2008; 49(10): 1601 - 1605.
[Abstract] [Full Text] [PDF]