SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Vascular and Endovascular Surgery
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Blebea, J.
Right arrow Articles by Atnip, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blebea, J.
Right arrow Articles by Atnip, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Duplex Imaging of the Renal Arteries with Contrast Enhancement

John Blebea, MD

Section of Vascular Surgery, Temple University, 3401 North Broad Street, Philadelphia, PA 19140 blebeaj{at}tuhs.temple.edu

Robert Zickler, MD

Division of Vascular Surgery, the Pennsylvania State University College of Medicine, Hershey, PA

Nikolaos Volteas, MD

Department of Surgery, Thessaloniki School of Medicine, Thessaloniki, Greece

Marsha Neumyer, RVT

Shahin Assadnia, MD

Karla Anderson, MD

Robert Atnip, MD

Division of Vascular Surgery, the Pennsylvania State University College of Medicine, Hershey, PA

Duplex ultrasound evaluation of the renal arteries is a technically challenging procedure. Its accuracy is significantly influenced by operator expertise and patient factors, such as overlying bowel gas and obesity. Intravenous microbubble contrast agents enhance vascular reflective acoustic signals and may improve ultrasound diagnostic accuracy. The clinical usefulness of such a contrast agent in the renal vasculature was examined prospectively. A total of 22 patients (16 males and 6 females) with mean age of 63 ±3 years with suspected abdominal vascular disease were studied prospectively. A complete color flow duplex imaging study of the renal vasculature was performed. This was then followed by an identical examination during which an ultrasound contrast agent (DefinityTM, DuPont Pharmaceutical) was infused intravenously at a rate of 2 to 4 mL/min. In addition to imaging of the vessels, the peak systolic velocity and Doppler waveforms of the aorta and renal arteries were examined. These results were independently compared to results with contrast angiography. A mean of 67 mL of contrast was used per patient. Of the total of 43 renal arteries examined, the accuracy for the detection of occlusions was 75% (3 of 4) for both standard and contrast-enhanced duplex ultrasound. The accuracy for the detection of hemodynamically significant stenosis was 50% (6 of 12) for standard and 75% (9 of 12) for contrast-enhanced duplex ultrasound. Visualization of normal or minimally diseased arteries was 94% (30 of 32) for standard and 97% (31 of 32) for contrast-enhanced ultrasound. Although overall accuracy was not enhanced by the infusion of ultrasound contrast, 5 of 7 arteries not visualized by color flow duplex were detected following the infusion of contrast agent, resulting in an additional 10% (5 of 48) of vessels visualized. Peak systolic velocities were increased by an average of 10% in normal or minimally diseased vessels and 12% in stenotic vessels following contrast administration but these differences were not statistically significant. Contrast-enhanced duplex imaging of the renal arteries is safe but not routinely required when performed by an experienced sonographer. However, it may increase visualization and accuracy in patients with stenoses or when the vessels are not initially visualized. Although increased velocities are seen when contrast agent is used, this does not appear to necessitate different Doppler criteria at this time.

Vascular and Endovascular Surgery, Vol. 37, No. 6, 429-436 (2003)
DOI: 10.1177/153857440303700607


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
G. J. Williams, P. Macaskill, S. F. Chan, T. E. Karplus, W. Yung, E. M. Hodson, and J. C. Craig
Comparative Accuracy of Renal Duplex Sonographic Parameters in the Diagnosis of Renal Artery Stenosis: Paired and Unpaired Analysis
Am. J. Roentgenol., March 1, 2007; 188(3): 798 - 811.
[Abstract] [Full Text] [PDF]



Advertisement