SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Vascular and Endovascular Surgery
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Okamoto, M.
Right arrow Articles by Nimura, Y.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Okamoto, M.
Right arrow Articles by Nimura, Y.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Flow Velocity Measurement and Differentiation Between True and False Lumens in Patients with Abdominal Aortic Dissection by Use of Pulsed Doppler Echocardiography

Mitsunori Okamoto

Department of Clinical Laboratory, Hiroshima University School of Medicine

Tokuo Tsubokura

Department of Clinical Laboratory, Hiroshima University School of Medicine

Goro Kajiyama

Department of Clinical Laboratory, Hiroshima University School of Medicine

Kunio Miyatake

Department of Internal Medicine, Hiroshima University School of Medicine, Hiroshima, and National Cardiovascular Center, Suita, Japan

Naokazu Kinoshita

Department of Internal Medicine, Hiroshima University School of Medicine, Hiroshima, and National Cardiovascular Center, Suita, Japan

Hiroshi Sakakibara

Department of Internal Medicine, Hiroshima University School of Medicine, Hiroshima, and National Cardiovascular Center, Suita, Japan

Yasuharu Nimura

Department of Internal Medicine, Hiroshima University School of Medicine, Hiroshima, and National Cardiovascular Center, Suita, Japan

Feasibility of differential diagnosis between the true and false lumens was studied with pulsed Doppler echocardiography in 8 patients with abdominal aortic dissection. The blood flow signal was obtained in both lumens in 7 of the 8 patients and in only the true lumen in the remaining 1 patient. The blood flow pattern was abruptly changed when the sample volume was moved from the true lumen to the false one. The peak flow velocity was higher in the true lumen (95 ± 19 cm/sec) than in the false one (28± 12 cm/sec) and ejection flow duration was longer in the former (306 ±103 ms) than in the latter (163 ±53 ms). The appearance time of ejection flow was not different between them. The presence of reverse flow during the ejection phase was more frequent in the false lumen (5/7) than in the true one (2/8). Thus, the conventional pulsed Doppler study may provide useful information in making a differential diagnosis between the true and false lumens in patients with abdominal aortic dissection.

Vascular and Endovascular Surgery, Vol. 24, No. 4, 265-270 (1990)
DOI: 10.1177/153857449002400409


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement